3-10 www. m oxa. com Ethernet Media Converters and Extenders Ethernet Media Converters and Extenders > 3 PTC-101 Series Environmental Type Tests Test Description Test Levels IEC 60068-2-1 Cold, operating (power ON/OFF) Test Ad -40°C, 48 hours IEC 60068-2-3 Damp heat, steady state, operating Test Ca 85°C, 95% R.H., 24 hours IEC 60068-2-14 Changing temperature, operating Test Nb -40 to 85°C, Ramp rate: 3°C/min, 8 cycles IEC 60068-2-48 IEC 60068-2-1 Cold, storage Test Ad -40°C, 12 hours IEC 60068-2-48 IEC 60068-2-3 Damp heat, steady state, storage Test Ca 90°C, 95% R.H., 24 hours IEC 60068-2-32 ISTA-2A Freefall, package Test Ed 90 cm IEC 60068-2-34 Random vibration, package Test Fd 3 grms (5 to 500 Hz) IEC 61850-3 IEC 60870-2-2 IEC 60068-2-6 IEC 60721-3-3 Vibration, operating Class Cm (3M6, 4M6) 20 m/s² (9 to 200 Hz) 15 m/s² (200 to 500 Hz) IEC 61850-3 IEC 60870-2-2 IEC 60068-2-27 IEC 60721-3-3 Shock, operating Class Cm (3M6, 4M6) 300 m/s², 11 ms Panel-Mounting Kit (Optional) Rear View Front View Side View PTC-101-M-ST-HV (other models available by request) Dimensions Unit: mm (inch) Power Requirements Input Voltage: Power Supply Type Power Consumption Fuse Rating LV-DC 20 to 72 VDC 170 mA @ 20 VDC 3.15A(T) 2 HV-AC 85 to 264 VAC 73 mA @ 85 VAC 3.15A(T) 2 HV-DC 88 to 300 VDC 47 mA @ 88 VDC 3.15A(T) 2 V-DC compliant with EN 50155 on 48 VDC HV-DC compliant with EN 50155 on 110 VDC Input Current: LV-DC: 170 mA @ 20 VDC max. HV-AC: 73 mA @ 85 VDC max. HV-DC: 47 mA @ 88 VDC max. Connection: Removable terminal block Overload Current Protection: 1.6 A (protects against two signals shorted together) Reverse Polarity Protection: Protects against V+/V- reversal Standards and Certifications Safety: UL 60950-1 EMC: EN 55022/24 EMI: CISPR 22, FCC Part 15B Class A EMS: EN 61000-4-2 (ESD): Contact: 8 kV; Air: 15 kV EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 (EFT): Power: 4 kV; Signal: 4 kV EN 61000-4-5 (Surge): Power: 4 kV; Signal: 4 kV EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 (PFMF) EN 61000-4-11 Green Product: RoHS, CRoHS, WEEE Note: Refer to the “Environmental Type Tests” table below for more detailed information. Freefall: IEC 60068-2-32 Power Automation: IEC 61850-3, IEEE 1613 Rail Traffic: EN 50121-4 *Please contact Moxa or a Moxa distributor for details. Vibration: IEC-61850-3, IEC-60870-2-2, EN 50125-3 (M12 models only) MTBF (mean time between failures) Time: 1,211,613 hrs Standard: Telcordia (Bellcore), GB Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty 144.15 (5.68) 8 (0.31) 67.4 (2.65) 15 (0.59) 19 (0.75) 26.2 (1.03) 26.06 (1.03) 30.5 (1.2) 34 (1.34) 51.6 (2.03) 54 (2.13) 67 (2.64) 101.4 (3.99) 111.4 (4.39) 123.46 (4.86) 135.1 (5.32) 66.65 (2.62)